public inbox for [email protected]  
help / color / mirror / Atom feed
From: Sandeep Thakkar <[email protected]>
To: Ertan Küçükoglu <[email protected]>
Cc: Thomas Munro <[email protected]>
Cc: Adrian Klaver <[email protected]>
Cc: [email protected]
Subject: Re: Windows installation problem at post-install step
Date: Mon, 5 Aug 2024 14:20:10 +0530
Message-ID: <CANFyU959RhJvRAY7=8vgN-1f+qKFuK80uFvrR1kMoQMQqzKPQg@mail.gmail.com> (raw)
In-Reply-To: <CANFyU94yoUCYovEZ9By2cpRbHsziRqndfPZ5qiTRD24CM57cEg@mail.gmail.com>
References: <CAH2i4ydECHZPxEBB7gtRG3vROv7a0d3tqAFXzcJWQ9hRsc1znQ@mail.gmail.com>
	<[email protected]>
	<CAH2i4yfkH7YPoLz1aE6MQiBOm8dra5uOTpn51=9ce_Tm6fy3Pw@mail.gmail.com>
	<[email protected]>
	<CAH2i4ycV8p_uDsdGRcP3bWcU52ogojg9_-mT8uMixSqpNmW7Sg@mail.gmail.com>
	<[email protected]>
	<CAH2i4yfBEYmOzsvsT=D+ySpLpsEW2O1VfUwx9Ckd69du67YY_w@mail.gmail.com>
	<[email protected]>
	<CA+hUKGJA4pGEeZtfUUEuQmNNO7x16wZ+RWOeXP+tq3Hf4iu8oQ@mail.gmail.com>
	<CANFyU95Le+trZbtB1D4Y1FdUu4y_OJLxvJMi1Zb9WOWuf8KpqA@mail.gmail.com>
	<CAH2i4ycX3Q79uv431CxZ9dcyM5jkL=sJ8Z8rbNaNuKSK=Bprfg@mail.gmail.com>
	<CANFyU95q_WDM+utY3Mnrf1pwgASN3ZR1r6Fb+Zs7kXsPEDQQ2A@mail.gmail.com>
	<CANFyU94yoUCYovEZ9By2cpRbHsziRqndfPZ5qiTRD24CM57cEg@mail.gmail.com>

Hi Thomas,

This issue is seen only on v16 and not the back branches (tested on 15 and
14) and also confirmed by @Ertan Küçükoglu <[email protected]> at
https://github.com/EnterpriseDB/edb-installers/issues/127#issuecomment-2268371442



On Fri, Aug 2, 2024 at 6:14 PM Sandeep Thakkar <
[email protected]> wrote:

>
>
> On Mon, Jul 22, 2024 at 6:10 PM Sandeep Thakkar <
> [email protected]> wrote:
>
>>
>>
>> On Mon, Jul 22, 2024 at 5:52 PM Ertan Küçükoglu <
>> [email protected]> wrote:
>>
>>> Sandeep Thakkar <[email protected]>, 22 Tem 2024 Pzt,
>>> 15:01 tarihinde şunu yazdı:
>>>
>>>>
>>>> When I checked the installation log shared by Ertan, I do see that the
>>>> locale passed to initcluster script is the same as returned by the
>>>> getlocales executable.
>>>>
>>>> Executing C:\Windows\System32\cscript //NoLogo "C:\Program
>>>> Files\PostgreSQL\16/installer/server/initcluster.vbs" "NT
>>>> AUTHORITY\NetworkService" "postgres" "****"
>>>> "C:\Users\User1\AppData\Local\Temp/postgresql_installer_cd79fad8b7"
>>>> "C:\Program Files\PostgreSQL\16" "C:\DATA_PG16" 5432 "Turkish,Türkiye" 0
>>>>
>>>
>>> That is log file line no 5544 and is cscript logging. There is no
>>> problem here.
>>> If you check log file line no 5606 you will see that the encoding is not
>>> correct just before initdb
>>> Maybe this is related to BAT file usage? I don't know.
>>>
>>> Ah, I see it now. Let me take a closer look
>>
>
> That line gets printed from within the initdb and is not printed by the
> script.
> @Thomas Munro <[email protected]>  I may be wrong but I guess fixing
> the code might fix this.
> Can you please share your patch so that I apply it on top of the last
> released
> source version, generate the installer and confirm the behaviour?
>
>
>>
>>> Thanks & Regards,
>>> Ertan
>>>
>>
>>
>> --
>> Sandeep Thakkar
>>
>>
>>
>
> --
> Sandeep Thakkar
>
>
>

-- 
Sandeep Thakkar


view thread (4+ messages)

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: [email protected]
  Cc: [email protected], [email protected], [email protected], [email protected], [email protected]
  Subject: Re: Windows installation problem at post-install step
  In-Reply-To: <CANFyU959RhJvRAY7=8vgN-1f+qKFuK80uFvrR1kMoQMQqzKPQg@mail.gmail.com>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by agora; see mirroring instructions
for how to clone and mirror all data and code used for this inbox