help / color / mirror / Atom feedFrom: Justin Pryzby <[email protected]>
To: samay sharma <[email protected]>
Cc: [email protected]
Cc: Peter Eisentraut <[email protected]>
Cc: Andres Freund <[email protected]>
Subject: Re: Documentation for building with meson
Date: Wed, 19 Oct 2022 21:43:12 -0500
Message-ID: <[email protected]> (raw)
In-Reply-To: <CAJxrbywFPcgC4nP_v+HHPhaYSWX2JL8FZXY2aFOZxXxTkTJJPw@mail.gmail.com>
References: <CAJxrbywFPcgC4nP_v+HHPhaYSWX2JL8FZXY2aFOZxXxTkTJJPw@mail.gmail.com>
On Wed, Oct 19, 2022 at 11:35:10AM -0700, samay sharma wrote:
> Creating a new thread focussed on adding docs for building Postgres with
> meson. This is a spinoff from the original thread [1] and I've attempted to
> address all the feedback provided there in the attached patch.
>
> Please let me know your thoughts.
It's easier to review rendered documentation.
I made a rendered copy available here:
https://api.cirrus-ci.com/v1/artifact/task/6084297781149696/html_docs/html_docs/install-meson.html
+ <application>Flex</application> and <application>Bison</application>
+ are needed to build <productname>PostgreSQL</productname> using
+ <application>meson</application>. Be sure to get
+ <application>Flex</application> 2.5.31 or later and
+ <application>Bison</application> 1.875 or later from your package manager.
+ Other <application>lex</application> and <application>yacc</application>
+ programs cannot be used.
These versions need to be updated, see also: 57bab3330:
- b086a47a270 "Bump minimum version of Bison to 2.3"
- 8b878bffa8d "Bump minimum version of Flex to 2.5.35"
+ will be enabled automatically if the required packages are found.
should refer to files/libraries/headers/dependencies rather than
"packages" ?
+ default is false that is to use <application>Readline</application>.
"that is to use" should be parenthesized or separate with commas, like
| default is false, that is to use <application>Readline</application>.
zlib is mentioned twice, the first being "strongly recommended".
Is that intended? Also, basebackup can use zlib, too.
+ If you have the binaries for certain by programs required to build
remove "by" ?
+ Postgres (with or without optional flags) stored at non-standard
+ paths, you could specify them manually to meson configure. The complete
+ list of programs for whom this is supported can be found by running
for *which
Actually, I suggest to say:
|If a program required to build Postgres (with or without optional flags)
|is stored in a non-standard path, ...
+ a build with a different value of these options.
.. with different values ..
+ the server, it is recommended to use atleast the <option>--buildtype=debug</option>
at least
+ and it's options in the meson documentation.
its
Maybe other things should have <productname> ?
Git
Libxml2
libxslt
visual studio
DTrace
ninja
+ <application>Flex</application> and <application>Bison</application>
Maybe these should use <productname> ?
+ be installed with <literal>pip</literal>.
Should be <application> ?
This part is redundant with prior text:
" To use this option, you will need an implementation of the Gettext API. "
+ Enabls use of the Zlib library
typo: Enabls
+ This option is set to true by default and setting it to false will
change "and" to ";" for spinlocks and atomics?
+ Debug info is generated but the result is not optimized.
Maybe say the "code" is not optimized ?
+ the tests can slow down the server significantly
remove "can"
+ You can override the amount of parallel processes used with
s/amount/number/
+ If you'd like to build with a backend other that ninja
other *than
+ the <acronym>GNU</acronym> C library then you will additionally
library comma
+ argument. If no <literal>srcdir</literal> is given Meson will deduce the
given comma
+ It should be noted that after the initial configure step
step comma
+ After the installation you can free disk space by removing the built
installation comma
+ To learn more about running the tests and how to interpret the results
+ you can refer to the documentation for interpreting test results.
interpret the results comma
"for interpreting test results" seems redundant.
+ ninja install should work for most cases but if you'd like to use more options
cases comma
Starting with "Developer Options", this intermixes postgres
project-specific options like cassert and tap-tests with meson's stuff
like buildtype and werror. IMO there's too much detail about meson's
options, which I think is better left to that project's own
documentation, and postgres docs should include only a brief mention and
a reference to their docs.
+ Ninja will automatically detect the number of CPUs in your computer and
+ parallelize itself accordingly. You can override the amount of parallel
+ processes used with the command line argument -j.
too much detail for my taste..
--
Justin
view thread (22+ messages) latest in thread
reply
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients using the --to and --cc options:
reply via email
To: [email protected]
Cc: [email protected], [email protected], [email protected], [email protected]
Subject: Re: Documentation for building with meson
In-Reply-To: <[email protected]>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by agora; see mirroring instructions