public inbox for [email protected]
help / color / mirror / Atom feedFrom: Amit Kapila <[email protected]>
To: Masahiko Sawada <[email protected]>
Cc: shveta malik <[email protected]>
Cc: Zhijie Hou (Fujitsu) <[email protected]>
Cc: Peter Smith <[email protected]>
Cc: Bertrand Drouvot <[email protected]>
Cc: Ajin Cherian <[email protected]>
Cc: Dilip Kumar <[email protected]>
Cc: Nisha Moond <[email protected]>
Cc: Hayato Kuroda (Fujitsu) <[email protected]>
Cc: Bharath Rupireddy <[email protected]>
Cc: Peter Eisentraut <[email protected]>
Cc: Bruce Momjian <[email protected]>
Cc: Ashutosh Sharma <[email protected]>
Cc: Andres Freund <[email protected]>
Cc: pgsql-hackers <[email protected]>
Cc: Alvaro Herrera <[email protected]>
Subject: Re: Synchronizing slots from primary to standby
Date: Thu, 1 Feb 2024 09:21:42 +0530
Message-ID: <CAA4eK1+7Bf=mqUu_pApmL7NiyoAZL2OaomuPEq2U1FH35skRDA@mail.gmail.com> (raw)
In-Reply-To: <CAD21AoAv6FwZ6UPNTj6=7A+3O2m4utzfL8ZGS6X1EGexikG66A@mail.gmail.com>
References: <[email protected]>
<CAJpy0uBc6H22RbNVU213AZ_BPw+uDptcTVHakKegpTCv74yN=w@mail.gmail.com>
<CAA4eK1JZDtRFPJaeaLvj74760pcvaEAVxNPN0+oW5A4jL1WCBg@mail.gmail.com>
<[email protected]>
<CAA4eK1JPB-zpGYTbVOP5Qp26tNQPMjDuYzNZ+a9RFiN5nE1tEA@mail.gmail.com>
<CAJpy0uAmbh_1pH-eG5bTbHXXq9w-uNV45DT-12TTh9kGj2HeCw@mail.gmail.com>
<CAFPTHDbsZ+pxAubb9d9BwVNt5OB3_2s77bG6nHcAgUPPhEVmMQ@mail.gmail.com>
<CAJpy0uBqS_HD30mBR0yD1SVCvUZDrw1=dwn1xH8ANEQw7gnPdw@mail.gmail.com>
<CAA4eK1Lxvfq9RwOEsguiMCrKPUc1He9UGz1_wi0N0cJaXFa4Eg@mail.gmail.com>
<OS0PR01MB5716E304C26E6ACE0BE84925947A2@OS0PR01MB5716.jpnprd01.prod.outlook.com>
<[email protected]>
<CAA4eK1K0jRXa2AhKXRVDY+Y42MG4RTbfAEcTBEGN2ov=Yjco+A@mail.gmail.com>
<OS0PR01MB571623B1D01003F99A7BB983947A2@OS0PR01MB5716.jpnprd01.prod.outlook.com>
<CAA4eK1+3jV839U3+DGgHrgrhtDguaVwAyb0Hucz9UbpjjVL=Sg@mail.gmail.com>
<OS0PR01MB5716DE2A364CB23F9144AED194782@OS0PR01MB5716.jpnprd01.prod.outlook.com>
<CAHut+PsaPJzbTAFjXkRE0uJYk+xNAdOHEnoBFTvazsRZfYSU3Q@mail.gmail.com>
<CAA4eK1+LnPajBsCXwCKbmOtDSJ=WWnXR+sHnTWav5OL3rebyyw@mail.gmail.com>
<CAJpy0uAv2dS+NTw1X1uZep11WM24Wog2kN1oqJu4Zx4xjpgwig@mail.gmail.com>
<CAA4eK1L6yoEs0OveL9xB+jopyp=Eps4ViU3JXhfpz0-2H3XCrg@mail.gmail.com>
<OS0PR01MB5716303C750A3D2FB71B77CD947E2@OS0PR01MB5716.jpnprd01.prod.outlook.com>
<CAA4eK1KkfVi-LCwHYd9B2xq-Q_2i0K-xwx1vnRoxFvG1n5SbNw@mail.gmail.com>
<CAJpy0uBwhbq=c+qYfnOifu0vTo1DvOxDnJCd1ragZxe2K8=nDw@mail.gmail.com>
<CAJpy0uBG6JgFSM7Bt0-1D+6u1H9K2+C6wvBanfiWcK9TupHnFw@mail.gmail.com>
<CAD21AoDUfnnxP+y2cg=LhP-bQXqFE1z4US-no=u30J7X=4Z6Aw@mail.gmail.com>
<CAA4eK1LwP-h6XSYg=Dgqos9k-t2vrwWJwXRbCk2QkeHSpoYEjQ@mail.gmail.com>
<CAD21AoAv6FwZ6UPNTj6=7A+3O2m4utzfL8ZGS6X1EGexikG66A@mail.gmail.com>
On Wed, Jan 31, 2024 at 9:20 PM Masahiko Sawada <[email protected]> wrote:
>
> On Wed, Jan 31, 2024 at 7:42 PM Amit Kapila <[email protected]> wrote:
> >
> >
> > Considering my previous where we don't want to restart for a required
> > parameter change, isn't it better to avoid repeated restart (say when
> > the user gave an invalid dbname)? BTW, I think this restart interval
> > is added based on your previous complaint [1].
>
> I think it's useful that the slotsync worker restarts immediately when
> a required parameter is changed but waits to restart when it exits
> with an error. IIUC the apply worker does so; if it restarts due to a
> subscription parameter change, it resets the last-start time so that
> the launcher will restart it without waiting.
>
Agreed, this idea sounds good to me.
> >
> > >
> > > ---
> > > When I dropped a database on the primary that has a failover slot, I
> > > got the following logs on the standby:
> > >
> > > 2024-01-31 17:25:21.750 JST [1103933] FATAL: replication slot "s" is
> > > active for PID 1103935
> > > 2024-01-31 17:25:21.750 JST [1103933] CONTEXT: WAL redo at 0/3020D20
> > > for Database/DROP: dir 1663/16384
> > > 2024-01-31 17:25:21.751 JST [1103930] LOG: startup process (PID
> > > 1103933) exited with exit code 1
> > >
> > > It seems that because the slotsync worker created the slot on the
> > > standby, the slot's active_pid is still valid.
> > >
> >
> > But we release the slot after sync. And we do take a shared lock on
> > the database to make the startup process wait for slotsync. There is
> > one gap which is that we don't reset active_pid for temp slots in
> > ReplicationSlotRelease(), so for temp slots such an error can occur
> > but OTOH, we immediately make the slot persistent after sync. As per
> > my understanding, it is only possible to get this error if the initial
> > sync doesn't happen and the slot remains temporary. Is that your case?
> > How did reproduce this?
>
> I created a failover slot manually on the primary and dropped the
> database where the failover slot is created. So this would not happen
> in normal cases.
>
Right, it won't happen in normal cases (say for walsender). This can
happen in some cases even without this patch as noted in comments just
above active_pid check in ReplicationSlotsDropDBSlots(). Now, we need
to think whether we should just update the comments above active_pid
check to explain this case or try to engineer some solution for this
not-so-common case. I guess if we want a solution we need to stop
slotsync worker temporarily till the drop database WAL is applied or
something like that.
> BTW I've tested the following switch/fail-back scenario but it seems
> not to work fine. Am I missing something?
>
> Setup:
> node1 is the primary, node2 is the physical standby for node1, and
> node3 is the subscriber connecting to node1.
>
> Steps:
> 1. [node1]: create a table and a publication for the table.
> 2. [node2]: set enable_syncslot = on and start (to receive WALs from node1).
> 3. [node3]: create a subscription with failover = true for the publication.
> 4. [node2]: promote to the new standby.
> 5. [node3]: alter subscription to connect the new primary, node2.
> 6. [node1]: stop, set enable_syncslot = on (and other required
> parameters), then start as a new standby.
>
> Then I got the error "exiting from slot synchronization because same
> name slot "test_sub" already exists on the standby".
>
> The logical replication slot that was created on the old primary
> (node1) has been synchronized to the old standby (node2). Therefore on
> node2, the slot's "synced" field is true. However, once node1 starts
> as the new standby with slot synchronization, the slotsync worker
> cannot synchronize the slot because the slot's "synced" field on the
> primary is false.
>
Yeah, we avoided doing anything in this case because the user could
have manually created another slot with the same name on standby.
Unlike WAL slots can be modified on standby as we allow decoding on
standby, so we can't allow to overwrite the existing slots. We won't
be able to distinguish whether the existing slot was a slot that the
user wants to sync with primary or a slot created on standby to
perform decoding. I think in this case user first needs to drop the
slot on new standby. We probably need to document it as well unless we
decide to do something else. What do you think?
--
With Regards,
Amit Kapila.
view thread (2+ messages)
reply
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients using the --to and --cc options:
reply via email
To: [email protected]
Cc: [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected]
Subject: Re: Synchronizing slots from primary to standby