public inbox for [email protected]  
help / color / mirror / Atom feed
From: John Naylor <[email protected]>
To: PostgreSQL Hackers <[email protected]>
Subject: do only critical work during single-user vacuum?
Date: Thu, 9 Dec 2021 15:28:18 -0400
Message-ID: <CAFBsxsFL5LoWanSLDjt_SjS9=FU_9XWi22iHMexRS2SubkX-Vw@mail.gmail.com> (raw)

When a user must shut down and restart in single-user mode to run
vacuum on an entire database, that does a lot of work that's
unnecessary for getting the system online again, even without
index_cleanup. We had a recent case where a single-user vacuum took
around 3 days to complete.

Now that we have a concept of a fail-safe vacuum, maybe it would be
beneficial to skip a vacuum in single-user mode if the fail-safe
criteria were not met at the beginning of vacuuming a relation. This
is not without risk, of course, but it should be much faster than
today and once up and running the admin would have a chance to get a
handle on things. Thoughts?

-- 
John Naylor
EDB: http://www.enterprisedb.com





view thread (32+ messages)  latest in thread

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: [email protected]
  Cc: [email protected], [email protected]
  Subject: Re: do only critical work during single-user vacuum?
  In-Reply-To: <CAFBsxsFL5LoWanSLDjt_SjS9=FU_9XWi22iHMexRS2SubkX-Vw@mail.gmail.com>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by agora; see mirroring instructions
for how to clone and mirror all data and code used for this inbox