public inbox for [email protected]  
help / color / mirror / Atom feed
From: shveta malik <[email protected]>
To: Amit Kapila <[email protected]>
Cc: Masahiko Sawada <[email protected]>
Cc: Zhijie Hou (Fujitsu) <[email protected]>
Cc: Dilip Kumar <[email protected]>
Cc: Bertrand Drouvot <[email protected]>
Cc: Peter Smith <[email protected]>
Cc: Nisha Moond <[email protected]>
Cc: Hayato Kuroda (Fujitsu) <[email protected]>
Cc: Bharath Rupireddy <[email protected]>
Cc: Peter Eisentraut <[email protected]>
Cc: Bruce Momjian <[email protected]>
Cc: Ashutosh Sharma <[email protected]>
Cc: Andres Freund <[email protected]>
Cc: pgsql-hackers <[email protected]>
Cc: Ajin Cherian <[email protected]>
Cc: Alvaro Herrera <[email protected]>
Cc: shveta malik <[email protected]>
Subject: Re: Synchronizing slots from primary to standby
Date: Tue, 16 Jan 2024 09:03:17 +0530
Message-ID: <CAJpy0uAU+nzufQwSzyB2YmhPHHn71_=1zkauP4Ra32a_eqbcig@mail.gmail.com> (raw)
In-Reply-To: <CAA4eK1+q8R=yEpTMiOZ_Xksdd_Jg3SXvBMxRutHQtkCbdeK_yQ@mail.gmail.com>
References: <CAA4eK1+AFY4E0f9h0-JF-navrf-vRMTMrN6H7PDKiR=C6p84Nw@mail.gmail.com>
	<CAJpy0uCcFKiofcp5V_hRvHrY_qVNX+eKvB0CPDNxSk2FbyMJCA@mail.gmail.com>
	<OS0PR01MB5716E731AC1B97A96B014B929460A@OS0PR01MB5716.jpnprd01.prod.outlook.com>
	<CAJpy0uDhR=m2Pr76aJZnvtKZpCEiLbMbjbPReCv5fS0MA3ch2w@mail.gmail.com>
	<CAJpy0uDWgSBUsTav1Eeo7E7i38GjXr_o0WdWamm3jGdctcoC4A@mail.gmail.com>
	<[email protected]>
	<CAJpy0uBGSjwhZTBo6MxT6TkwO2AX5fa1kw7UC3RQLiapUJReuw@mail.gmail.com>
	<CAFiTN-vTaWUh0Eq8UpETMk=ZGFEMkD-1gXtosODZeCiCfi92kQ@mail.gmail.com>
	<CAA4eK1KLR2BP1GULkA9FMj3aKFbOcQLvu6b5fAht+YjCVRkc1w@mail.gmail.com>
	<CAFiTN-skn=ffyC8PMzg7gfpyNLfx7v9roae-+W8HYbpzoO0mkg@mail.gmail.com>
	<OS0PR01MB57169DD55EC8D9D1EDB7A0C2946A2@OS0PR01MB5716.jpnprd01.prod.outlook.com>
	<CAA4eK1L74EUU7+Dr11joY+Xact_MsjZu9G12sX+vRUWJsptP8Q@mail.gmail.com>
	<CAA4eK1+ORhnb2zUUpO_FcgWUUbwvQX5+=tdCehx7x2nB2x8VMg@mail.gmail.com>
	<CAD21AoCoX+jhy_i3v+T2s78NG_0HH1oXOUiTOWhDdxVPBtDHKA@mail.gmail.com>
	<CAJpy0uAwz9iNw3=5QC8S3z8Bf-w0z27rE32SFxjDMer7aTQMPg@mail.gmail.com>
	<CAA4eK1+q8R=yEpTMiOZ_Xksdd_Jg3SXvBMxRutHQtkCbdeK_yQ@mail.gmail.com>

On Sat, Jan 13, 2024 at 12:54 PM Amit Kapila <[email protected]> wrote:
>
> On Fri, Jan 12, 2024 at 5:50 PM shveta malik <[email protected]> wrote:
> >
> > There are multiple approaches discussed and tried when it comes to
> > starting a slot-sync worker. I am summarizing all here:
> >
> >  1) Make slotsync worker as an Auxiliary Process (like checkpointer,
> > walwriter, walreceiver etc). The benefit this approach provides is, it
> > can control begin and stop in a more flexible way as each auxiliary
> > process could have different checks before starting and can have
> > different stop conditions. But it needs code duplication for process
> > management(start, stop, crash handling, signals etc) and currently it
> > does not support db-connection smoothly (none of the auxiliary process
> > has one so far)
> >
>
> As slotsync worker needs to perform transactions and access syscache,
> we can't make it an auxiliary process as that doesn't initialize the
> required stuff like syscache. Also, see the comment "Auxiliary
> processes don't run transactions ..." in AuxiliaryProcessMain() which
> means this is not an option.
>
> >
> > 2) Make slotsync worker as a 'special' process like AutoVacLauncher
> > which is neither an Auxiliary process nor a bgworker one. It allows
> > db-connection and also provides flexibility to have start and stop
> > conditions for a process.
> >
>
> Yeah, due to these reasons, I think this option is worth considering
> and another plus point is that this allows us to make enable_syncslot
> a PGC_SIGHUP GUC rather than a PGC_POSTMASTER.
>
> >
> > 3) Make slotysnc worker a bgworker. Here we just need to register our
> > process as a bgworker (RegisterBackgroundWorker()) by providing a
> > relevant start_time and restart_time and then the process management
> > is well taken care of. It does not need any code-duplication and
> > allows db-connection smoothly in registered process. The only thing it
> > lacks is that it does not provide flexibility of having
> > start-condition which then makes us to have 'enable_syncslot' as
> > PGC_POSTMASTER parameter rather than PGC_SIGHUP. Having said this, I
> > feel enable_syncslot is something which will not be changed frequently
> > and with the benefits provided by bgworker infra, it seems a
> > reasonably good option to choose this approach.
> >
>
> I agree but it may be better to make it a PGC_SIGHUP parameter.
>
> > 4) Another option is to have Logical Replication Launcher(or a new
> > process) to launch slot-sync worker. But going by the current design
> > where we have only 1 slotsync worker, it may be an overhead to have an
> > additional manager process maintained.
> >
>
> I don't see any good reason to have an additional launcher process here.
>
> >
> > Thus weighing pros and cons of all these options, we have currently
> > implemented the bgworker approach (approach 3).  Any feedback is
> > welcome.
> >
>
> I vote to go for (2) unless we face difficulties in doing so but (3)
> is also okay especially if others also think so.

I am not against any of the approaches but I still feel that when we
have a standard way of doing things (bgworker) we should not keep
adding code to do things in a special way unless there is a strong
reason to do so. Now we need to decide if 'enable_syncslot' being
PGC_POSTMASTER is a strong reason to go the non-standard way? If yes,
then we should think of option 2 else option 3 seems better in my
understanding (which may be limited due to my short experience here),
so I am all ears to what others think on this.

thanks
Shveta






view thread (100+ messages)  latest in thread

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: [email protected]
  Cc: [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected]
  Subject: Re: Synchronizing slots from primary to standby
  In-Reply-To: <CAJpy0uAU+nzufQwSzyB2YmhPHHn71_=1zkauP4Ra32a_eqbcig@mail.gmail.com>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by agora; see mirroring instructions
for how to clone and mirror all data and code used for this inbox