Received: from localhost (maia-1.hub.org [200.46.204.191]) by postgresql.org (Postfix) with ESMTP id 4F5F19FBA95 for ; Wed, 11 Jul 2007 15:54:03 -0300 (ADT) Received: from postgresql.org ([200.46.204.71]) by localhost (mx1.hub.org [200.46.204.191]) (amavisd-maia, port 10024) with ESMTP id 82172-01 for ; Wed, 11 Jul 2007 15:53:55 -0300 (ADT) X-Greylist: from auto-whitelisted by SQLgrey-1.7.5 Received: from westnet.com (westnet.com [216.187.52.2]) by postgresql.org (Postfix) with ESMTP id CD0AA9FBA30 for ; Wed, 11 Jul 2007 15:53:57 -0300 (ADT) Received: from westnet.com (localhost [127.0.0.1]) by westnet.com (8.14.0/8.14.0) with ESMTP id l6BIru7r012337 for ; Wed, 11 Jul 2007 14:53:56 -0400 (EDT) Received: from localhost (gsmith@localhost) by westnet.com (8.14.0/8.13.2/Submit) with ESMTP id l6BIru1A012334 for ; Wed, 11 Jul 2007 14:53:56 -0400 (EDT) X-Authentication-Warning: westnet.com: gsmith owned process doing -bs Date: Wed, 11 Jul 2007 14:53:56 -0400 (EDT) From: Greg Smith X-X-Sender: gsmith@westnet.com To: pgsql-performance@postgresql.org Subject: Re: WALL on controller without battery? In-Reply-To: <200707110847.44612@hal.medialogik.com> Message-ID: References: <20070711153620.GP1241@phlogiston.dyndns.org> <200707110847.44612@hal.medialogik.com> MIME-Version: 1.0 Content-Type: TEXT/PLAIN; charset=US-ASCII; format=flowed X-Virus-Scanned: Maia Mailguard 1.0.1 X-Archive-Number: 200707/114 X-Sequence-Number: 25798 On Wed, 11 Jul 2007, Alan Hodgson wrote: > Presumably he'll have the 2-port configured for write-through operation. This is the real key to his question. In order to get acceptable performance for the operating system, Francisco may very well need the OS disks to be configured in write-back mode. If that's the case, then he can't put the WAL there; it has to go onto the array with the BBU. > I would spring for a 4-port with a BBU, though, and then put the WAL on the > drives with the OS. This is certainly worth considering. When putting multiple RAID controllers into a system, I always try to keep them of a similar grade because it improves the possibility of data recovery in case of a controller failure. For example, if he had a 4-port with BBU and an 8-port with BBU, the 8-port could be split into two 4-disk RAID-6 volumes, and then in an emergency or for troubleshooting isolation you could always get any data you needed off any 4-disk set with either controller. The little 2-disk unit is providing no such redundancy. -- * Greg Smith gsmith@gregsmith.com http://www.gregsmith.com Baltimore, MD