X-Original-To: pgsql-performance-postgresql.org@localhost.postgresql.org Received: from localhost (mx1.hub.org [200.46.208.251]) by postgresql.org (Postfix) with ESMTP id 8B6DD11F690E for ; Mon, 24 Apr 2006 16:01:00 -0300 (ADT) Received: from postgresql.org ([200.46.204.71]) by localhost (mx1.hub.org [200.46.208.251]) (amavisd-new, port 10024) with ESMTP id 64829-01-8 for ; Mon, 24 Apr 2006 16:00:30 -0300 (ADT) X-Greylist: from auto-whitelisted by SQLgrey- Received: from wumpus.mythic-beasts.com (wumpus.mythic-beasts.com [212.69.37.9]) by postgresql.org (Postfix) with ESMTP id A8B5411F9508 for ; Mon, 24 Apr 2006 11:36:26 -0300 (ADT) Received: from sphinx.mythic-beasts.com ([212.69.37.6]) by wumpus.mythic-beasts.com with esmtp (Exim 4.44) id 1FY2Ar-00069J-Qe for pgsql-performance@postgresql.org; Mon, 24 Apr 2006 15:36:25 +0100 Received: from xelah (helo=localhost) by sphinx.mythic-beasts.com with local-esmtp (Exim 4.51) id 1FY2Ar-000365-08 for pgsql-performance@postgresql.org; Mon, 24 Apr 2006 15:36:25 +0100 Date: Mon, 24 Apr 2006 15:36:24 +0100 (BST) From: Alex Hayward X-X-Sender: xelah@sphinx.mythic-beasts.com To: Pgsql performance Subject: Re: Hardware: HP StorageWorks MSA 1500 In-Reply-To: <444C29ED.2070901@paradise.net.nz> Message-ID: References: <7F10D26ECFA1FB458B89C5B4B0D72C2B3E4009@sesrv12.wirelesscar.com> <444C29ED.2070901@paradise.net.nz> MIME-Version: 1.0 Content-Type: TEXT/PLAIN; charset=US-ASCII X-Virus-Scanned: Maia Mailguard 1.0.1 X-Archive-Number: 200604/527 X-Sequence-Number: 18611 On Mon, 24 Apr 2006, Mark Kirkwood wrote: > If I'm reading the original post correctly, the biggest issue is likely > to be that the 14 disks on each 2Gbit fibre channel will be throttled to > 200Mb/s by the channel , when in fact you could expect (in RAID 10 > arrangement) to get about 7 * 70 Mb/s = 490 Mb/s. The two controllers and two FC switches/hubs are intended for redundancy, rather than performance, so there's only one 2Gbit channel. I don't know if its possible to use both in parallel to get better performance. I believe it's possible to join two or more FC ports on the switch together, but as there's only port going to the controller internally this presumably wouldn't help. There are two SCSI U320 buses, with seven bays on each. I don't know what the overhead of SCSI is, but you're obviously not going to get 490MB/s for each set of seven even if the FC could do it. Of course your database may not spend all day doing sequential scans one at a time over 14 disks, so it doesn't necessarily matter...