From: PG Bug reporting form <noreply@postgresql.org>
To: pgsql-bugs@lists.postgresql.org
Cc: buschmann@nidsa.net
Subject: BUG #15641: Autoprewarm worker fails to start on Windows with huge pages in use
Date: Mon, 18 Feb 2019 17:56:55 +0000
Message-ID: <15641-377d62c43f94b645@postgresql.org> (raw)
The following bug has been logged on the website:
Bug reference: 15641
Logged by: Hans Buschmann
Email address: buschmann@nidsa.net
PostgreSQL version: 11.2
Operating system: Windows Server 2019 Standard
Description:
I recently moved a production system from PG 10.7 to 11.2 on a different
Server.
The configuration settings where mostly taken from the old system and
enhanced by new features of PG 11.
pg_prewarm was used for a long time (with no specific configuration).
Now I have added Huge page support for Windows in the OS and verified it
with vmmap tool from Sysinternals to be active.
(the shared buffers are locked in memory: Lock_WS is set).
When pg_prewarm.autoprewarm is set to on (using the default after initial
database import via pg_restore), the autoprewarm worker process
terminates immediately and generates a huge number of logfile entries
like:
CPS PRD 2019-02-17 16:11:53 CET 00000 11:> LOG: background worker
"autoprewarm worker" (PID 3996) exited with exit code 1
CPS PRD 2019-02-17 16:11:53 CET 55000 1:> ERROR: could not map dynamic
shared memory segment
There seem no timeout or waiting time to restart the autoprewarm worker in
this case.
The problem can be circumvented by disabling pg_prewarm.autoprewarm.
This behavior is transported by pg_basebackup to a physical replication
database with the same problem.
In my opinion the shared memory mapping of pr_prewarm is not aware of the
huge pages in windows and fails.
Unfortunatly I am not able to investigate the problem in the source code.
Configuration:
- Windows Server 2019 x64 (should be independent of this windows version)
- PG 11.2 64bit from EDB download on PostgeSQL Website
- Huge pages authorized in OS and verified to be used
- pg_prewarm loaded to database
With best regards
Hans Buschmann
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients from your mail client; the link fills in
the headers below: reply via email
Some clients, webmail especially, drop In-Reply-To and References from
a link, and the reply then starts a new thread: use the mbox below.
To: pgsql-bugs@postgresql.org
Cc: noreply@postgresql.org, buschmann@nidsa.net
Subject: Re: BUG #15641: Autoprewarm worker fails to start on Windows with huge pages in use
In-Reply-To: <15641-377d62c43f94b645@postgresql.org>
References: <15641-377d62c43f94b645@postgresql.org>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox