Andrew Bartley wrote:
>
> Thanks Justin,
>
> I suppose the reason for the question is related to the limit on the number
> trans before there is a problem.
No stress. One of the developers will be able to answer you in regards
to this. :) If no-one pipes up and says anything, then it's worth
asking on the PostgreSQL Hackers mailing list
(pgsql-hackers@postgresql.org).
> Regarding the static type app tables I keep referring to. These tables are
> period based. i.e. At the end of the period these tables are loaded and
> vacuumed, then used for reporting purposes only. In the next/new period a
> new table will be created added to/updated, then closed at the end of the
> period. The tables are dynamically accessed using "execute" based on the
> period selected in the report criteria requested by the user from the GUI.
>
> The tables in question will never change from the point when the period is
> closed.
Ok, after they're loaded it's worth doing an ANALYZE to ensure the
planner statistics and similar are updated and made accurate. After
that though, as they're totally static you'd be wasting your time
running VACUUM or any further ANALYZE's on them.
> Thanks for your help and info.
That's cool. :)
Regards and best wishes,
Justin Clift
> Andrew
--
"My grandfather once told me that there are two kinds of people: those
who work and those who take the credit. He told me to try to be in the
first group; there was less competition there."
- Indira Gandhi
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients from your mail client; the link fills in
the headers below: reply via email
Some clients, webmail especially, drop In-Reply-To and References from
a link, and the reply then starts a new thread: use the mbox below.
To: pgsql-general@postgresql.org
Cc: justin@postgresql.org, abartley@evolvosystems.com
Subject: Re: Vacuum full
In-Reply-To: <3DC88E3F.402DB9CB@postgresql.org>
References: <003a01c28536$9f4395d0$3200a8c0@abartleypc> <3DC8782B.A7979D94@postgresql.org> <004301c2853c$f0072fd0$3200a8c0@abartleypc> <3DC88358.67D35777@postgresql.org> <004801c28542$acbe17b0$3200a8c0@abartleypc> <3DC88E3F.402DB9CB@postgresql.org>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox