public inbox for [email protected]  
help / color / mirror / Atom feed
From: Drouvot, Bertrand <[email protected]>
To: Amit Kapila <[email protected]>
Cc: Zhijie Hou (Fujitsu) <[email protected]>
Cc: shveta malik <[email protected]>
Cc: Peter Smith <[email protected]>
Cc: Hayato Kuroda (Fujitsu) <[email protected]>
Cc: Bharath Rupireddy <[email protected]>
Cc: Peter Eisentraut <[email protected]>
Cc: Bruce Momjian <[email protected]>
Cc: Ashutosh Sharma <[email protected]>
Cc: Andres Freund <[email protected]>
Cc: pgsql-hackers <[email protected]>
Cc: Ajin Cherian <[email protected]>
Cc: Alvaro Herrera <[email protected]>
Subject: Re: Synchronizing slots from primary to standby
Date: Fri, 1 Dec 2023 12:15:16 +0100
Message-ID: <[email protected]> (raw)
In-Reply-To: <CAA4eK1LxGd8GACR36KdtbVaQeKsV9B5-LuBf2o721x6OZ=_wWg@mail.gmail.com>
References: <CAJpy0uC+2agRtF3H=n-hW5JkoPfaZkjPXJr==y3_PRE04dQvhw@mail.gmail.com>
	<CAJpy0uAT-oGsgmb4dC=dYYRNY7WXEAAWGWU2kL5phLz3Wcdifg@mail.gmail.com>
	<CAA4eK1J=-kPHS1eHNBtzOQHZ64j6WSgSYQZ3fH=2vfiwy_48AA@mail.gmail.com>
	<CAJpy0uB_y_1akXUWM9WnSdQ-NVWTnHTpmNu6gJQ5tnyuAMTUOg@mail.gmail.com>
	<CAHut+Pv-yu71ogj_hRi6cCtmD55bsyw7XTxj1Nq8yVFKpY3NDQ@mail.gmail.com>
	<OS0PR01MB571646B8186F6A06404BD50194BDA@OS0PR01MB5716.jpnprd01.prod.outlook.com>
	<OS0PR01MB57161C27BCFAF04C2B48B47394BDA@OS0PR01MB5716.jpnprd01.prod.outlook.com>
	<[email protected]>
	<CAJpy0uDKPK537ZW8CAjDVmSjHtBKCzTUzq=it84SrA0PfoWFCg@mail.gmail.com>
	<OS0PR01MB57161938A348977127D56A6694BDA@OS0PR01MB5716.jpnprd01.prod.outlook.com>
	<[email protected]>
	<OS0PR01MB5716DCFD6CC89C2F243B55939483A@OS0PR01MB5716.jpnprd01.prod.outlook.com>
	<[email protected]>
	<CAA4eK1LxGd8GACR36KdtbVaQeKsV9B5-LuBf2o721x6OZ=_wWg@mail.gmail.com>

Hi,

On 12/1/23 12:06 PM, Amit Kapila wrote:
> On Wed, Nov 29, 2023 at 3:24 PM Drouvot, Bertrand
> <[email protected]> wrote:
>> I think I'm fine with documenting the fact that the user should not change the failover
>> value. But if he does change it (because at the end nothing prevents it to do so) then
>> I think the meaning of subfailoverstate should still make sense.
>>
> 
> How user can change the slot's failover property? Do we provide any
> command for it?

It's doable, using a replication connection:

"
$ psql replication=database
psql (17devel)
Type "help" for help.

postgres=# ALTER_REPLICATION_SLOT logical_slot6 (FAILOVER false);
ALTER_REPLICATION_SLOT
"

Regards,

-- 
Bertrand Drouvot
PostgreSQL Contributors Team
RDS Open Source Databases
Amazon Web Services: https://aws.amazon.com






view thread (108+ messages)  latest in thread

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: [email protected]
  Cc: [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected]
  Subject: Re: Synchronizing slots from primary to standby
  In-Reply-To: <[email protected]>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by agora; see mirroring instructions
for how to clone and mirror all data and code used for this inbox