help / color / mirror / Atom feedFrom: shveta malik <[email protected]>
To: Masahiko Sawada <[email protected]>
Cc: Bertrand Drouvot <[email protected]>
Cc: Amit Kapila <[email protected]>
Cc: Zhijie Hou (Fujitsu) <[email protected]>
Cc: Dilip Kumar <[email protected]>
Cc: Peter Smith <[email protected]>
Cc: Nisha Moond <[email protected]>
Cc: Hayato Kuroda (Fujitsu) <[email protected]>
Cc: Bharath Rupireddy <[email protected]>
Cc: Peter Eisentraut <[email protected]>
Cc: Bruce Momjian <[email protected]>
Cc: Ashutosh Sharma <[email protected]>
Cc: Andres Freund <[email protected]>
Cc: pgsql-hackers <[email protected]>
Cc: Ajin Cherian <[email protected]>
Cc: Alvaro Herrera <[email protected]>
Cc: shveta malik <[email protected]>
Subject: Re: Synchronizing slots from primary to standby
Date: Fri, 19 Jan 2024 15:55:24 +0530
Message-ID: <CAJpy0uDfgZcJxTcmnRoiL8zNfRht-iMGb51_CyGJ6ybxjT4H2w@mail.gmail.com> (raw)
In-Reply-To: <CAD21AoBgzONdt3o5mzbQ4MtqAE=WseiXUOq0LMqne-nWGjZBsA@mail.gmail.com>
References: <CAA4eK1L74EUU7+Dr11joY+Xact_MsjZu9G12sX+vRUWJsptP8Q@mail.gmail.com>
<CAA4eK1+ORhnb2zUUpO_FcgWUUbwvQX5+=tdCehx7x2nB2x8VMg@mail.gmail.com>
<CAD21AoCoX+jhy_i3v+T2s78NG_0HH1oXOUiTOWhDdxVPBtDHKA@mail.gmail.com>
<CAJpy0uAwz9iNw3=5QC8S3z8Bf-w0z27rE32SFxjDMer7aTQMPg@mail.gmail.com>
<CAA4eK1+q8R=yEpTMiOZ_Xksdd_Jg3SXvBMxRutHQtkCbdeK_yQ@mail.gmail.com>
<CAJpy0uAU+nzufQwSzyB2YmhPHHn71_=1zkauP4Ra32a_eqbcig@mail.gmail.com>
<CAA4eK1KtwFg6Mr1MRnHUUfPotzc2=5UCTq_D2t8x0PM1Lyhk8g@mail.gmail.com>
<CAD21AoA03f0QKYjiSymGcnROvh1X-3YSqyB-19mkRXt5dfaxFw@mail.gmail.com>
<CAJpy0uCneiKeNuz3B91Wf2LRxAenD3fpaxYfdL09y9qHmvVp+w@mail.gmail.com>
<CAJpy0uCJ7MKgZnKLAACd-AXN0VbWM5gVJ+GRJ1Za_A2UmF3R0A@mail.gmail.com>
<[email protected]>
<CAJpy0uBc6H22RbNVU213AZ_BPw+uDptcTVHakKegpTCv74yN=w@mail.gmail.com>
<CAD21AoBgzONdt3o5mzbQ4MtqAE=WseiXUOq0LMqne-nWGjZBsA@mail.gmail.com>
On Fri, Jan 19, 2024 at 10:35 AM Masahiko Sawada <[email protected]> wrote:
>
>
> Thank you for updating the patch. I have some comments:
>
> ---
> + latestWalEnd = GetWalRcvLatestWalEnd();
> + if (remote_slot->confirmed_lsn > latestWalEnd)
> + {
> + elog(ERROR, "exiting from slot synchronization as the
> received slot sync"
> + " LSN %X/%X for slot \"%s\" is ahead of the
> standby position %X/%X",
> + LSN_FORMAT_ARGS(remote_slot->confirmed_lsn),
> + remote_slot->name,
> + LSN_FORMAT_ARGS(latestWalEnd));
> + }
>
> IIUC GetWalRcvLatestWalEnd () returns walrcv->latestWalEnd, which is
> typically the primary server's flush position and doesn't mean the LSN
> where the walreceiver received/flushed up to.
yes. I think it makes more sense to use something which actually tells
flushed-position. I gave it a try by replacing GetWalRcvLatestWalEnd()
with GetWalRcvFlushRecPtr() but I see a problem here. Lets say I have
enabled the slot-sync feature in a running standby, in that case we
are all good (flushedUpto is the same as actual flush-position
indicated by LogstreamResult.Flush). But if I restart standby, then I
observed that the startup process sets flushedUpto to some value 'x'
(see [1]) while when the wal-receiver starts, it sets
'LogstreamResult.Flush' to another value (see [2]) which is always
greater than 'x'. And we do not update flushedUpto with the
'LogstreamResult.Flush' value in walreceiver until we actually do an
operation on primary. Performing a data change on primary sends WALs
to standby which then hits XLogWalRcvFlush() and updates flushedUpto
same as LogstreamResult.Flush. Until then we have a situation where
slots received on standby are ahead of flushedUpto and thus slotsync
worker keeps one erroring out. I am yet to find out why flushedUpto is
set to a lower value than 'LogstreamResult.Flush' at the start of
standby. Or maybe am I using the wrong function
GetWalRcvFlushRecPtr() and should be using something else instead?
[1]:
Startup process sets 'flushedUpto' here:
ReadPageInternal-->XLogPageRead-->WaitForWALToBecomeAvailable-->RequestXLogStreaming
[2]:
Walreceiver sets 'LogstreamResult.Flush' here but do not update
'flushedUpto' here:
WalReceiverMain(): LogstreamResult.Write = LogstreamResult.Flush =
GetXLogReplayRecPtr(NULL)
> Does it really happen
> that the slot's confirmed_flush_lsn is higher than the primary's flush
> lsn?
It may happen if we have not configured standby_slot_names on primary.
In such a case, slots may get updated w/o confirming that standby has
taken the change and thus slot-sync worker may fetch the slots which
have lsns ahead of the latest WAL position on standby.
thanks
Shveta
view thread (119+ messages) latest in thread
reply
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients using the --to and --cc options:
reply via email
To: [email protected]
Cc: [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected], [email protected]
Subject: Re: Synchronizing slots from primary to standby
In-Reply-To: <CAJpy0uDfgZcJxTcmnRoiL8zNfRht-iMGb51_CyGJ6ybxjT4H2w@mail.gmail.com>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by agora; see mirroring instructions
for how to clone and mirror all data and code used for this inbox