From: Inoue, Hiroshi <h-inoue@dream.email.ne.jp>
To: michael.riksman@khalda-eg.com
Cc: pgsql-odbc@postgresql.org
Subject: Re: Rockwell FactoryTalk Says 'SQL_TIMESTAMP data type is not supported'
Date: Mon, 29 Jul 2019 13:33:09 +0900
Message-ID: <ff0ed851-4cf4-e89e-2e69-b6d9ed163206@dream.email.ne.jp> (raw)
In-Reply-To: <8d59c6fb05384b0a9b3352dea36c5ca2@SB-MBX-02.KHALDA-EG.com>
References: <6962f3d9-d8e0-0e11-9c84-0b855a7ac249@dream.email.ne.jp>
<E3D77610-4272-4EAF-8776-E3A8733B9062@khalda-eg.com>
<7fd5b1b9-9e21-1caa-7d39-026e003113ba@dream.email.ne.jp>
<1169e59dc8dc4202be1d2fab835bd1fb@SB-MBX-02.KHALDA-EG.com>
<54f4ae2c-1182-0b8d-db4a-57a41b4bb7d3@dream.email.ne.jp>
<6567bd3971464a87b748c1cabe867519@SB-MBX-02.KHALDA-EG.com>
<f1251aae-64d9-621d-5e51-11127f77c47a@dream.email.ne.jp>
<6e492e58757549089c3b63a6a1d391d7@SB-MBX-02.KHALDA-EG.com>
<c03f94d2-de4d-1bb5-590f-6b7296c98cd2@dream.email.ne.jp>
<64908e4b78a9407ba529e850d81e7cbc@SB-MBX-02.KHALDA-EG.com>
<8315b938-5edc-125f-bf58-a3fb65c524c1@dream.email.ne.jp>
<8d59c6fb05384b0a9b3352dea36c5ca2@SB-MBX-02.KHALDA-EG.com>
Hi Michael,
On 2019/07/28 16:45, michael.riksman@khalda-eg.com wrote:
>
> Hey,
>
> I’m not sure what happened, but after restarting the PC, it started
> working. I am sure I restarted after installing the driver, but
> perhaps I didn’t…?
>
> But we have data!
>
> THANK YOU SO MUCH!
>
> I am curious – what was the original error with TIMESTAMP? What lines
> of code did you change?
>
I would commit the following change.
inline patch 1: info.c (+1/-2 lines) download inline-1.patchdiff --git a/info.c b/info.cindex 452dabf..c2dc0aa 100644--- a/info.c+++ b/info.c@@ -1155,8 +1155,8 @@ PGAPI_GetTypeInfo(HSTMT hstmt,
{
EnvironmentClass *env = CC_get_env(conn);
- /* Filter unsupported data types */- if (EN_is_odbc2(env))+ /* Filter unsupported data types when fSqlType = SQL_ALL_TYPES */
+ if (SQL_ALL_TYPES == fSqlType && EN_is_odbc2(env))
{
switch (sqlType)
{
Since commit 778571, SQLGetTypeInfo() filters SQL_TYPE_DATE,
SQL_TYPE_TIME and SQL_TYPE_TIMESTAMP for ODBC 2.x applications. However
it doesn't seem appropriate to filter them for individual
SQLGetTypeInfo(.., SQL_DATE/TIME/TIMESTAMP) because Microsoft ODBC
driver manager calls SQLGetTypeInfo(.., SQL_TYPE_DATE/TIME/TIMESTAMP) of
ODBC 3.x drivers when ODBC 2.x applications call SQLGetTypeInfo(..,
SQL_DATE/TIME/TIMESTAMP).
** The behavior of unixODBC is different.
regards,
Hiroshi Inoue
> Thanks.
>
> Regards,
>
> Michael Riksman
>
> Instrument and Control Specialist
>
> Khalda Petroleum Co.
>
> A KPC/Apache Corp. Joint Venture
>
> Salam Base, Egypt
>
> Mob: +20 122 0530603
>
> Email: michael.riksman@khalda-eg.com
>
> *From:*Inoue, Hiroshi [mailto:h-inoue@dream.email.ne.jp]
> *Sent:* Friday, 26 July 2019 2:29 PM
> *To:* Michael Riksman (Salam - Gas)
> *Cc:* pgsql-odbc@postgresql.org
> *Subject:* Re: Rockwell FactoryTalk Says 'SQL_TIMESTAMP data type is
> not supported'
>
> Hi,
>
> On 2019/07/25 15:27, michael.riksman@khalda-eg.com
> <mailto:michael.riksman@khalda-eg.com> wrote:
>
> Hey,
>
> I turned it on;
>
> But the only time something is written to the trace is when I open
> up the configuration window, and click OK;
>
>
>
> postgreSQL
>
> 51 ‘Tags in Model’
>
> SQLpostgres.LOG
>
>
>
> Microsoft SQL
>
> 17 ‘Tags in Model’
>
> SQLmsql.LOG
>
> But when I right-click and start the DataLog;
>
> Nothing is added to the SQL.LOG file/ODBC Tracing.
>
> Data is successfully being logged to Microsoft SQL at this point –
> but still no additional data in the ODBC Tracing.
>
>
> So there seems no ODBC API call.
> Would you like to see the page
> www.plctalk.net/qanda/archive/index.php/t-109368.html
> <http://www.plctalk.net/qanda/archive/index.php/t-109368.html; ?
>
> regards,
> Hiroshi Inoue
>
>
> Regards,
>
> Michael Riksman
>
> Instrument and Control Specialist
>
> Khalda Petroleum Co.
>
> A KPC/Apache Corp. Joint Venture
>
> Salam Base, Egypt
>
> Mob: +20 122 0530603
>
> Email: michael.riksman@khalda-eg.com
> <mailto:michael.riksman@khalda-eg.com>
>
---
このメールは、AVG によってウイルス チェックされています。
http://www.avg.comAttachments:image001.png (image/png, 13.5K) downloadview imageimage002.jpg (image/jpeg, 3.9K) downloadview imageimage003.jpg (image/jpeg, 14.7K) downloadview imageimage004.jpg (image/jpeg, 15.1K) downloadview imageimage005.jpg (image/jpeg, 22.2K) downloadview image
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients from your mail client; the link fills in
the headers below: reply via email
Some clients, webmail especially, drop In-Reply-To and References from
a link, and the reply then starts a new thread: use the mbox below.
To: pgsql-odbc@postgresql.org
Cc: h-inoue@dream.email.ne.jp, michael.riksman@khalda-eg.com
Subject: Re: Rockwell FactoryTalk Says 'SQL_TIMESTAMP data type is not supported'
In-Reply-To: <ff0ed851-4cf4-e89e-2e69-b6d9ed163206@dream.email.ne.jp>
References: <6962f3d9-d8e0-0e11-9c84-0b855a7ac249@dream.email.ne.jp> <E3D77610-4272-4EAF-8776-E3A8733B9062@khalda-eg.com> <7fd5b1b9-9e21-1caa-7d39-026e003113ba@dream.email.ne.jp> <1169e59dc8dc4202be1d2fab835bd1fb@SB-MBX-02.KHALDA-EG.com> <54f4ae2c-1182-0b8d-db4a-57a41b4bb7d3@dream.email.ne.jp> <6567bd3971464a87b748c1cabe867519@SB-MBX-02.KHALDA-EG.com> <f1251aae-64d9-621d-5e51-11127f77c47a@dream.email.ne.jp> <6e492e58757549089c3b63a6a1d391d7@SB-MBX-02.KHALDA-EG.com> <c03f94d2-de4d-1bb5-590f-6b7296c98cd2@dream.email.ne.jp> <64908e4b78a9407ba529e850d81e7cbc@SB-MBX-02.KHALDA-EG.com> <8315b938-5edc-125f-bf58-a3fb65c524c1@dream.email.ne.jp> <8d59c6fb05384b0a9b3352dea36c5ca2@SB-MBX-02.KHALDA-EG.com> <ff0ed851-4cf4-e89e-2e69-b6d9ed163206@dream.email.ne.jp>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox