david@lang.hm wrote:
> I could see a raid 1 array not doing consistancy checking (after all,
> it has no way of knowing what's right if it finds an error), but since
> raid 5/6 can repair the data I would expect them to do the checking
> each time.
Your messages are spread across the thread. :-)
RAID 5 cannot repair the data. I don't know much about RAID 6, but I
expect it cannot necessarily repair the data either. It still doesn't
know which drive is wrong. In any case, there is no implementation I am
aware of that performs mandatory consistency checks on read. This would
be silliness.
Cheers,
mark
--
Mark Mielke <mark@mielke.cc>
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients using the --to and --cc options:
reply via email
To: pgsql-performance@postgresql.org
Cc: mark@mark.mielke.cc, david@lang.hm, fw@deneb.enyo.de, fhevia@ip-tel.com.ar
Subject: Re: With 4 disks should I go for RAID 5 or RAID 10
In-Reply-To: <4772CED1.2070808@mark.mielke.cc>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox