pg.ddx.io  pgsql-performance@postgresql.org mailing list archive  
help / color / mirror / Atom feed
From: Arjen van der Meijden <acmmailing@tweakers.net>
To: pgsql-performance@postgresql.org
Subject: Re: Request for feedback on hardware for a new database server
Date: Fri, 18 Mar 2011 08:16:56 +0100
Message-ID: <4D8306E8.6020701@tweakers.net> (raw)
In-Reply-To: <AANLkTi=UcB8x337Hhmbs1VG93vCBRWbYJnTAsUSaX5c2@mail.gmail.com>
References: <871v25jlnb.fsf@googlemail.com>
	<AANLkTi=UcB8x337Hhmbs1VG93vCBRWbYJnTAsUSaX5c2@mail.gmail.com>

On 18-3-2011 4:02 Scott Marlowe wrote:
> On Thu, Mar 17, 2011 at 6:51 PM, Oliver Charles
> <postgresql-perf@ocharles.org.uk>  wrote:
>
> Another point.  My experience with 1U chassis and cooling is that they
> don't move enough air across their cards to make sure they stay cool.
> You'd be better off ordering a 2U chassis with 8 3.5" drive bays so
> you can add drives later if you need to, and it'll provide more
> cooling air across the card.
>
> Our current big 48 core servers are running plain LSI SAS adapters
> without HW RAID because the LSI 8888s we were using overheated and
> cooked themselves to death after about 3 months.  Those are 1U chassis
> machines, and our newer machines are all 2U boxes now.

We have several 1U boxes (mostly Dell and Sun) running and had several 
in the past. And we've never had any heating problems with them. That 
includes machines with more power hungry processors than are currently 
available, all power slurping FB-dimm slots occupied and two raid cards 
installed.

But than again, a 2U box will likely have more cooling capacity, no 
matter how you look at it.

Another tip that may be useful; look at 2.5" drives. Afaik there is no 
really good reason to use 3.5" drives for new servers. The 2.5" drives 
save power and room - and thus may allow more air flowing through the 
enclosure - and offer the same performance and reliability (the first I 
know for sure, the second I'm pretty sure of but haven't seen much proof 
of lately).

You could even have a 8- or 10-disk 1U enclosure in that way or up to 24 
disks in 2U. But those configurations will require some attention to 
cooling again.

Best regards,

Arjen



view thread (11+ messages)  latest in thread

Message-ID: <4D8306E8.6020701@tweakers.net>
Permalink:  ../4D8306E8.6020701@tweakers.net/
Also on:    postgresql.org/message-id/4D8306E8.6020701@tweakers.net

 · 

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: pgsql-performance@postgresql.org
  Cc: acmmailing@tweakers.net
  Subject: Re: Request for feedback on hardware for a new database server
  In-Reply-To: <4D8306E8.6020701@tweakers.net>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox