On 3/13/2013 1:23 PM, Steve Crawford wrote:
>
> What concerns me more than wear is this:
>
> InfoWorld Article:
> http://www.infoworld.com/t/solid-state-drives/test-your-ssds-or-risk-massive-data-loss-researchers-w...
>
>
> Referenced research paper:
> https://www.usenix.org/conference/fast13/understanding-robustness-ssds-under-power-fault
>
>
> Kind of messes with the "D" in ACID.
It is somewhat surprising to discover that many SSD products are not
durable under sudden power loss (what where they thinking!?, and ...why
doesn't anyone care??).
However, there is a set of SSD types known to be designed to address
power loss events that have been tested by contributors to this list.
Use only those devices and you won't see this problem. SSDs do have a
wear-out mechanism but wear can be monitored and devices replaced in
advance of failure. In practice longevity is such that most machines
will be in the dumpster long before the SSD wears out. We've had
machines running with several hundred wps constantly for 18 months using
Intel 710 drives and the wear level SMART value is still zero.
In addition, like any electronics module (CPU, memory, NIC), an SSD can
fail so you do need to arrange for valuable data to be replicated.
As with old school disk drives, firmware bugs are a concern so you might
want to consider what would happen if all the drives of a particular
type all decided to quit working at the same second in time (I've only
seen this happen myself with magnetic drives, but in theory it could
happen with SSD).
--
Sent via pgsql-performance mailing list (pgsql-performance@postgresql.org)
To make changes to your subscription:
http://www.postgresql.org/mailpref/pgsql-performance
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients using the --to and --cc options:
reply via email
To: pgsql-performance@postgresql.org
Cc: david_list@boreham.org
Subject: Re: New server setup
In-Reply-To: <5140DE90.5010009@boreham.org>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox