From: Lending, Rune <rune.lending@inpoc.com>
To: 'pgsql-performance@postgresql.org' <pgsql-performance@postgresql.org>
Subject: pg_autovacuum parameters
Date: Tue, 3 Aug 2004 11:09:26 +0200
Message-ID: <A177ACC01D78D4118FC100508BAE3F7AF653BB@TELECOMMAIL> (raw)
Hello all.
I am managing a large database with lots of transactions in different
tables.
The largest tables have around 5-6 millions tuples and around 50000-60000
inserts and maybe 20000 updates pr day.
While the smalest tables have only a few tuples and a few updates /inserts
pr day. In addition we have small tables with many updates/inserts. So what
I am saying is that there is all kinds of tables and uses of tables in our
database.
This, I think, makes it difficult to set up pg_autovacuum. I am now running
vacuum jobs on different tables in cron.
What things should I consider when setting but base and threshold values in
pg_autovacuum? Since the running of vacuum and analyze is relative to the
table size, as it must be, I think it is difficult to cover all tables..
Are there anyone who have some thoughts around this?
Regards
Rune
Reply instructions:
You may reply publicly to this message via plain-text email
using any one of the following methods:
* Reply to all the recipients using the --to and --cc options:
reply via email
To: pgsql-performance@postgresql.org
Cc: rune.lending@inpoc.com
Subject: Re: pg_autovacuum parameters
In-Reply-To: <A177ACC01D78D4118FC100508BAE3F7AF653BB@TELECOMMAIL>
* Save the following mbox file, import it into your mail client,
and reply-to-all from there: mbox
This inbox is served by DDX for PostgreSQL; see mirroring instructions
for how to clone and mirror all data and code used for this inbox