pg.ddx.io  pgsql-performance@postgresql.org mailing list archive  
help / color / mirror / Atom feed
From: Harsh Azad <harsh.azad@gmail.com>
To: david@lang.hm <david@lang.hm>
Cc: Decibel! <decibel@decibel.org>
Cc: pgsql-performance@postgresql.org
Subject: Re: SAN vs Internal Disks
Date: Wed, 12 Sep 2007 11:14:27 +0530
Message-ID: <a199704d0709112244j2ebe5f6cpfd36a4c9e81e2aee@mail.gmail.com> (raw)
In-Reply-To: <Pine.LNX.4.64.0709111649230.23876@asgard.lang.hm>
References: <a199704d0709060535q6fea139aq2e3863e685555b0d@mail.gmail.com>
	<a199704d0709061003u71d536fbh9d71ed095dfe16b@mail.gmail.com>
	<Pine.GSO.4.64.0709062354040.28915@westnet.com>
	<20070907100446.GE1795@mathom.us>
	<20070907103341.GC20896@oppetid.no>
	<Pine.LNX.4.64.0709071400430.19737@asgard.lang.hm>
	<20070911205550.GA38801@decibel.org>
	<20070911210857.GQ1795@mathom.us>
	<20070911230744.GJ38801@decibel.org>
	<Pine.LNX.4.64.0709111649230.23876@asgard.lang.hm>

Yeah, the DAS we are considering is Dell MD3000, it has redundant hot
swappable raid controllers in active-active mode. Provision for hot spare
hard-disk. And it can take upto 15 disks in 3U, you can attach two more
MD1000 to it, giving a total of 45 disks in total.

-- Harsh

On 9/12/07, david@lang.hm <david@lang.hm> wrote:
>
> On Tue, 11 Sep 2007, Decibel! wrote:
>
> > On Tue, Sep 11, 2007 at 05:09:00PM -0400, Michael Stone wrote:
> >> On Tue, Sep 11, 2007 at 03:55:51PM -0500, Decibel! wrote:
> >>> Also, to reply to someone else's email... there is one big reason to
> use
> >>> a SAN over direct storage: you can do HA that results in 0 data loss.
> >>> Good SANs are engineered to be highly redundant, with multiple
> >>> controllers, PSUs, etc, so that the odds of losing the SAN itself are
> >>> very, very low. The same isn't true with DAS.
> >>
> >> You can get DAS arrays with multiple controllers, PSUs, etc.  DAS !=
> >> single disk.
> >
> > It's still in the same chassis, though, which means if you lose memory
> > or mobo you're still screwed. In a SAN setup for redundancy, there's
> > very little in the way of a single point of failure; generally only the
> > backplane, and because there's very little that's on there it's
> > extremely rare for one to fail.
>
> not nessasarily. direct attached doesn't mean in the same chassis,
> external drive shelves attached via SCSI are still DAS
>
> you can even have DAS attached to a pair of machines, with the second box
> configured to mount the drives only if the first one dies.
>
> David Lang
>
> ---------------------------(end of broadcast)---------------------------
> TIP 2: Don't 'kill -9' the postmaster
>



-- 
Harsh Azad
=======================
Harsh.Azad@gmail.com

view thread (37+ messages)  latest in thread

Message-ID: <a199704d0709112244j2ebe5f6cpfd36a4c9e81e2aee@mail.gmail.com>
Permalink:  ../a199704d0709112244j2ebe5f6cpfd36a4c9e81e2aee@mail.gmail.com/
Also on:    postgresql.org/message-id/a199704d0709112244j2ebe5f6cpfd36a4c9e81e2aee@mail.gmail.com

 · 

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: pgsql-performance@postgresql.org
  Cc: harsh.azad@gmail.com, david@lang.hm, decibel@decibel.org
  Subject: Re: SAN vs Internal Disks
  In-Reply-To: <a199704d0709112244j2ebe5f6cpfd36a4c9e81e2aee@mail.gmail.com>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by DDX for PostgreSQL; see mirroring instructions