public inbox for [email protected]  
help / color / mirror / Atom feed
From: Dave Page <[email protected]>
To: Aditya Toshniwal <[email protected]>
Cc: pgadmin-hackers <[email protected]>
Subject: Re: [pgAdmin][RM4310] User can not connect to the Master Password with Enter button
Date: Mon, 10 Jun 2019 10:04:27 +0100
Message-ID: <CA+OCxozgD-eUgFDKwkMjuUEt3v25PsEDpMX+Kkp2qKsSctzs2A@mail.gmail.com> (raw)
In-Reply-To: <CAM9w-_mn7mBrAcpBqMayPPU-btXenfX5+YKmsp_8w5qFd0903w@mail.gmail.com>
References: <CAM9w-_mhLAoL3ZgY3w8SCH6WbSF=_11tU3Ueh-voAWkfgVZtVw@mail.gmail.com>
	<CA+OCxowteeh7yjQLToCGWPtFsqSKK10E3wX6o8k8i5Rub-DoGA@mail.gmail.com>
	<CAM9w-_mn7mBrAcpBqMayPPU-btXenfX5+YKmsp_8w5qFd0903w@mail.gmail.com>

Hi

On Wed, Jun 5, 2019 at 1:39 PM Aditya Toshniwal <
[email protected]> wrote:

> Hi,
>
> On Wed, Jun 5, 2019 at 4:48 PM Dave Page <[email protected]> wrote:
>
>> Hi
>>
>> On Wed, Jun 5, 2019 at 8:14 AM Aditya Toshniwal <
>> [email protected]> wrote:
>>
>>> Hi Hackers,
>>>
>>> Attached is the patch to fix an issue where using browser autofills in
>>> alertify dialogs triggers the help page button (#4317).
>>> A workaround was added to master password dialog to avoid this, but that
>>> in turn disabled the 'OK' button tigger on pressing enter button. This is
>>> also fixed with this patch.(#4310)
>>>
>>
>> This isn't quite right. When the browser auto-fills the password, the OK
>> button remains disabled. I can hit enter though - however, I shouldn't be
>> able to do that when the OK button is disabled (being the default button on
>> the dialogue, it should respond to enter, unless another control which also
>> accepts enter has focus (e.g. a multiline text area).
>>
> The autofilled password appears as set, but it is actually not set to
> textbox unless you enter/click in the dropdown. We get the DOM element
> value as blank even if it appears filled. This is how chromium autofill
> behaves. Upon hitting enter the autofill value is set to the textbox and OK
> button is enabled.
>
>>
>> The OK button should be enabled - probably all the time, as the user
>> could have entered a blank password, and most systems won't prevent a user
>> from trying to use such a password.
>>
> I have made the changes to allow blank master password, plus enabling OK
> button always. Attached is the updated patch.
>

I think you've slightly mis-understood what I was trying to say.

- We should not allow a blank password.
- We should not disable the OK button at all.

My analogy was focussed on the fact that most systems never disable OK
buttons on login dialogues, as some of those systems (but not all of
course) may allow blank passwords.

-- 
Dave Page
Blog: http://pgsnake.blogspot.com
Twitter: @pgsnake

EnterpriseDB UK: http://www.enterprisedb.com
The Enterprise PostgreSQL Company


view thread (6+ messages)  latest in thread

reply

Reply instructions:

You may reply publicly to this message via plain-text email
using any one of the following methods:

* Reply to all the recipients using the --to and --cc options:
  reply via email

  To: [email protected]
  Cc: [email protected], [email protected]
  Subject: Re: [pgAdmin][RM4310] User can not connect to the Master Password with Enter button
  In-Reply-To: <CA+OCxozgD-eUgFDKwkMjuUEt3v25PsEDpMX+Kkp2qKsSctzs2A@mail.gmail.com>

* Save the following mbox file, import it into your mail client,
  and reply-to-all from there: mbox

This inbox is served by agora; see mirroring instructions
for how to clone and mirror all data and code used for this inbox